Appliance Coupler Number of Standard Sheet for Infomations Appliance Inlet(male) Connector(female) C2
C1
Rated current of appliance coupler (A)
0.2
Class of equipment II Maximum temperature of appliance inlet 70℃ Rewirable construction allowed No Lightest type allowed 60227 IEC 41 Minimum cross-section (mm) —(1) Standard sheet of IEC 60083 A 1-15 , B , C 5 C6
C5
Rated current of appliance coupler (A) 2.5Class of equipment I Maximum temperature of appliance inlet 70℃ Rewirable construction allowed No Lightest type allowed 60227 IEC 52 Minimum cross-section (mm) 0.75 Standard sheet of IEC 60083 A 5-15 , B 2 , C 2b , C 4 C8
C7
Rated current of appliance coupler (A) 2.5Class of equipment II Maximum temperature of appliance inlet 70℃ Rewirable construction allowed No Lightest type allowed 60227 IEC 52 Minimum cross-section (mm) 0.75(2) Standard sheet of IEC 60083 A 1-15 , B 2 , C 5 , C 6 C10
C9
Rated current of appliance coupler (A)
6
Class of equipment II Maximum temperature of appliance inlet 70℃ Rewirable construction allowed No Lightest type allowed 60227 IEC 52 Minimum cross-section (mm) 0.75 Standard sheet of IEC 60083 A 1-15 , B 2 , C 6 C14
C13
Rated current of appliance coupler (A) 10Class of equipment I Maximum temperature of appliance inlet 70℃ Rewirable construction allowed Yes Lightest type allowed 60227 IEC 53 or 60245 IEC 53 Minimum cross-section (mm) 0.75(3) Standard sheet of IEC 60083 A 5-15 , B 2 , C 2b , C 3b , C 4 C16
C15
Rated current of appliance coupler (A)
10Class of equipment I Maximum temperature of appliance inlet 120℃ Rewirable construction allowed Yes Lightest type allowed 60245 IEC 53 or 60245 IEC 51 Minimum cross-section (mm) 0.75(3) Standard sheet of IEC 60083 A 5-15 , B 2 , C 2b , C 3b , C 4 C16A
C15A
Rated current of appliance coupler (A)
10
Class of equipment I Maximum temperature of appliance inlet 155℃ Rewirable construction allowed Yes Lightest type allowed 60245 IEC 53 or 60245 IEC 51 Minimum cross-section (mm) 0.75(3) Standard sheet of IEC 60083 A 5-15 , B 2 , C 2b , C 3b , C 4 C18
C17
Rated current of appliance coupler (A)
10Class of equipment II Maximum temperature of appliance inlet 70℃ Rewirable construction allowed No Lightest type allowed 60227 IEC 53 or 60245 IEC 53 Minimum cross-section (mm) 0.75(3) Standard sheet of IEC 60083 A 1-15 , B 2 , C 6 C20
C19
Rated current of appliance coupler (A) 16Class of equipment I Maximum temperature of appliance inlet 70℃ Rewirable construction allowed Yes Lightest type allowed 60227 IEC 53 or 60245 IEC 53 Minimum cross-section (mm) 1(3) Standard sheet of IEC 60083 A 5-15 , B 2 , C 2b , C 3b , C 4 C22
C21
Rated current of appliance coupler (A)
16
Class of equipment I Maximum temperature of appliance inlet 155℃ Rewirable construction allowed Yes Lightest type allowed 60245 IEC 53 or 60245 IEC 51 Minimum cross-section (mm) 1(3) Standard sheet of IEC 60083 A 5-15 , B 2 , C 2b , C 3b , C 4 C24
C23
Rated current of appliance coupler (A)
16
Class of equipment II Maximum temperature of appliance inlet 70℃ Rewirable construction allowed No Lightest type allowed 60227 IEC 53 or 60245 IEC 53 Minimum cross-section (mm) 1(3) Standard sheet of IEC 60083 A 1-15 , B 2 , C 6 1. (1)Only for small hand-held appliances, in length not exceeding 2 m, if allowed by the relevant appliance standard.2. (2)0,5 mm2 is allowed for lengths not exceeding 2 m.
3. (3)If the cord has a length exceeding 2 m or is of the retractable coiled (pre-coiled) type, nominal cross-sectional areas shall be – 1 mm2 for 10 A connectors – 1.5 mm2 for 16 A connectors